Details, Fiction And M Bola

i have some m bola problem about welding inspection , my issue is can we apply vaccum box testing in butt weld joint for roof or base. ( for Misc tank)

b. click here to read All radial joints among sections of your drip rings, as well as among the drip ring look at more info plus the annular plate or base, see post shall be

saya mohon kiranya format laporan inspeksi tersebut dapat dikirimkan juga ke e mail saya sebagai referensi. [email protected]. Terima kasih

Ø Vacuum box examined utilizing a basics exam force at least 3 psi gauge or as specified on enterprise specification.

Assamualaikum, saya ingin bertanya mengenai peaking & banding. Sekarang saya terlibat dalam kerja membuat storage tank & kaedah yang kami gunakan untuk erect tank adalah jacking method, and that is we must erect the tank ranging from top rated to base. So we presently concluded the twelfth training course till eleventh training course such as the roofing. Them my QC really previously did the peaking and banding for shell plate but some of the readings have been exceed the tolerance specified in API 650 that's +-13mm.

to see more, which include how to manage cookies, see here: Cookie coverage %d bloggers like this:

Ø If the ensuing thickness is below minimum needed According to hydrostatic examination layout disorders, re-welding is necessary.

nanya dunk, boleh nggak klo pada spot base tank kita nggak make annular plate, hanya menggunakan bottom sketch.

Maaf ya pak saya barangkali banyak bertanya sama bapak saya masih junior bapak…..saya jg bertanya sama pak Yoseph.

qualifications saya teknik m bola sipil, tapi diminta mengevaluasi plumbness dan roundness oil storage tank. Bapak Lukman, tolong saya minta dibantu untuk informasi standard plumbness dan roundness (no code dan isinya)

six. After complete designed up check weld steel with Dye Penetrant check to guarantee the weld is nice and no crack.

the m bola tank bottom and foundation. Unless the Purchaser specifies in any other case, the ring shall meet the next demands

Kabar baik selalu…thks banget atas infonya nih click to read more bro…oh iya tapi di apendix M…aku lupa tepat pasalnya M berapa…disana juga m bola dikatakan bahwa Anular digunakan pada tanki dengan diameter diatas 30 meter.

Ø fixing defective welds shall be finished by chipping or melting out the defects from one or both equally side of joint, as essential, and carry on with re-welding. All fixed welds are matter to get re-examined as specified previously mentioned.