Kabar baik selalu…thks banget atas infonya nih bro…oh iya tapi di apendix M…aku lupa tepat pasalnya M berapa…disana juga dikatakan bahwa Anular digunakan pada tanki dengan diameter diatas 30 meter.

Ø Inspection by radiographic system isn't required for roof-plate or base-plate welds, for welds becoming a member of roof plates to top angle, the best angle to your shell plates, shell plates to base plates, or appurtenances to tanks.

Mohon kiranya format laporan inspeksi tersebut dapat dikirimkan juga ke e-mail saya sebagai referensi Pak

I'm sorry…I in no way produce specification for vacuum box however, if u want to create vacuum box specification I recommend to Keep to helpful hints the rule in API 650 but more strictness. be sure to focus on it with all your engineering Division

Ø Should the ensuing thickness is below minimum article amount demanded as per hydrostatic exam style and design situations, re-welding is needed.

b. All radial joints involving sections on the drip rings, and involving the drip ring and the annular plate or bottom, shall be

...................................................................................................................... mu bola net

history saya teknik sipil, tapi diminta mengevaluasi plumbness dan roundness oil storage tank. Bapak Lukman, tolong recommended reading saya minta dibantu untuk informasi normal plumbness dan roundness (no code dan isinya)

kalau harus mengacu pada bare minimum yS dikarenakan dalam 1 group tidak ada yang sama atau lebih besar minimal YSnya dari FE 52C boleh tidak digantikan oleh product di team VI yang mempunyai least YS yang lebih tinggi dari YS group VI.

Clipping can be a handy way to collect important slides you wish to return to later on. Now personalize the name of the clipboard to retail store your clips.

Welds that are unsuccessful to fulfill the standards specified in paragraph over, shall be reworked just before hydrostatic testing as follows mu bola net :

Maaf ya pak saya barangkali banyak bertanya sama bapak saya masih junior bapak…..saya jg bertanya sama pak Yoseph.

Ø Vacuum box analyzed employing a check stress no less than three psi gauge or as specified on Company specification.

all rectangular and sketch plates (bottom plates on which the shell rests that have one particular end rectangular) shall Have a very minimum amount

Saya mau minta data tentang storage tank operator, kira2 ability yang dibutuhkan apa saja ya pak? dan metode dalam mengoperasikan storage tank tersebut my sources seperti apa? apa cara mengoperasikan n maintenance aboveground storage tank dan underground storage tank berbeda? jika ya, berbeda dalam hal apa?